Though never directly articulated by data center authority, the current practice surrounding these critical facilities has frequently been “The cooler, the greater.Inch However, some leading server manufacturers and knowledge center efficiency experts share the opinion that data centers can run far hotter compared to what they do today without having to sacrifice uptime with an enormous savings both in cooling related costs and CO2 emissions. One server manufacturer lately announced their rack of servers can operate with inlet temperatures at 104 deg F.

How come it want to push the envelope? The cooling infrastructure is definitely an energy hog. This technique, operating 24x7x365, consumes lots of electricity to produce the perfect computing atmosphere, which might hover between 55 to 65 deg F. (The present “suggested” vary from ASHRAE is eighteen-27 C or 64.4 deg F through 80.6 deg F)

To attain efficiencies, numerous influential finish users are running their data centers warmer and therefore are counseling their contemporaries to follow along with suit. However the process is not as easy as raising the thermostat in your house. Here are the key arguments and factors:

Position: Raising server inlet temperature will realize significant energy savings.

Arguments for:

o Sun Microsystems, both a leading hardware manufacturer and knowledge center operator, estimates a 4% savings in energy costs for each one (1) degree rise in server inlet temperature. (Miller, 2007)

o A greater temperature setting often means more hrs of “free-cooling” possible through air-side or water side economizers. This post is especially compelling for an area like San Jose, California, where outdoors air (dry-bulb) climate is at or below 70 deg F for 82% of the season. Based on geography, the annual savings from economization could exceed six figures.

Arguments Against:

o The cooling infrastructure has certain design setpoints. How can we realize that raising server inlet temperature will not lead to false economy, causing additional, unnecessary consumption in other components such as the server fans, pumps, or compressors?

o Free-cooling, while ideal for new data centers, is definitely an costly proposition for existing ones. The whole cooling infrastructure will need re-engineering and could be expensive and unnecessarily complex.

o Costs from thermal-related complete breakdowns or downtime will counterbalance the savings recognized from the greater temperature setpoint.

Position: Raising server inlet temperature complicates reliability, recovery, and equipment warranties.

Arguments for:

o Inlet air and exhaust air frequently add an information center. Climate is stored low to offset this mixing and also to keep your server inlet temperature within ASHRAE’s suggested range. Raising the temperature could exacerbate already-existing hotspots.

o Awesome temperatures offer an envelope of awesome air within the room, a good thing within the situation of the air conditioning failure. Employees might have additional time to identify and repair and, if required, shut lower equipment gracefully.

o Within the situation from the 104 degree F server, what is the chance every device-from storage to networking-would perform reliability? Would really warranties remain valid at 104 deg F?